MIK-MDC-P1 Single Channel Universal Controller pH/ORP

The MDC-P1/P2 is an advanced, intelligent online multi-parameter controller capable of supporting up to two channels.The first channel's hybrid mode allows for the connection of either analog or digital sensors, while the second channel connects digital sensors.

Characteristics

Measured variables:pH / ORP / Antimony

Measuring ranges:pH/Antimony:(-2.00 ~ 16.00) pH ORP:(-2000 ~ 2000) mV

Temperature range:(-10~130)℃

Digital sensor input:pH/ORP/Conductivity/Dissolved Oxygen/Turbidity/Sludge Concentration/Inductive Conductivity/Residual/Chlorine/Ammonia nitrogen/Nitrate nitrogen/COD, etc.

  • Introduction

The MDC-P1/P2 is an advanced, intelligent online multi-parameter controller capable of supporting up to two channels.The first channel's hybrid mode allows for the connection of either analog or digital sensors, while the second channel connects digital sensors. This controller  can  measure a variety of parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, sludge concentration, residual chlorine, ammonia nitrogen, nitrate nitrogen, COD, and more.   Its continuous monitoring data can be transmitted to a DCS system via output transmission or communicated with a computer using the Modbus-RTU protocol via RS485 interface for remote monitoring and logging. It can also control cleaning systems or pumps. The controller offers an optional NB-IoT wireless transmission module,users can access real-time site conditions  on mobile devices. This controller is widely used in various industries including thermal power, chemical fertilizers, metallurgy, environmental protection, pharmaceuticals, biochemistry,food, sewage, semiconductors, and tap water.

MIK-MDC-P1 Single Channel Universal Controller pH/ORPMIK-MDC-P1 Single Channel Universal Controller pH/ORP

  • Technical parameters
Measured variables pH / ORP / Antimony
Measuring ranges pH/Antimony:(-2.00 ~ 16.00) pH ORP:(-2000 ~ 2000) mV
Input impedance ≥1012Ω
Temperature types NTC10K ,Pt1000 ,Pt100
Temperature range (-10~130)℃
Accuracy pH:±0.02pH
Antimony:±0.2pH
ORP:±2mV
NTC10K:(-10~60)℃, accuracy: ±0.3℃ (60~130)℃, accuracy: ±2℃
Pt1000 accuracy: ±0.3℃
Pt100 accuracy: ±0.3℃
Resolution pH/Antimony:0.01pH; ORP:1mV
Repeatability 0.02pH
Temperature   compensation Manual compensation;
Automatic compensation: Linear, Acid, Base, Pure
Digital sensor input
Measured variables pH/ORP/Conductivity/Dissolved Oxygen/Turbidity/Sludge Concentration/Inductive Conductivity/Residual/Chlorine/Ammonia nitrogen/Nitrate nitrogen/COD, etc.
Measuring ranges pH: (0.00 ~ 14.00) pH
ORP: (-2000 ~ 2000) mV
Dissolved oxygen: (0~40) mg/L
Saturation: (0~200)%
Conductivity: (0~500) mS/cm
Turbidity: (0~4000) NTU
Sludge concentration: (0~120000) mg/L
Inductive conductivity: (0~2000) mS/cm
Residual chlorine: (0~ 100) mg/L
Ammonia nitrogen: (0~ 1000) mg/L
Nitrate nitrogen: (0~ 1000) mg/L
COD: (0~ 1500) mg/L
Note:  Actual  measurement  ranges  should  refer  to   the technical data of the connected sensors.

MIK-MDC-P1 Single Channel Universal Controller pH/ORPMIK-MDC-P1 Single Channel Universal Controller pH/ORPMIK-MDC-P1 Single Channel Universal Controller pH/ORPMIK-MDC-P1 Single Channel Universal Controller pH/ORP

MIK-MDC-P1 Single Channel Universal Controller pH/ORPMIK-MDC-P1 Single Channel Universal Controller pH/ORP